Pain in the
Lower leg
30mn
Phase 1
lower leg
Pain in the
ankle and
Ankle
Achilles
30mn
Phase 1
tendon
problem
Phase 1
Pain in
Foot
30mn
Phase 2
the foot
Phase 3
4.3.3. ELECTRICAL MUSCLE STIMULATION (EMS) PROGRAMMES
These programmes, commonly called "neuromuscular electrical stimulation" (NMES) or "elec-
tromyostimulation", emit impulses to cause a muscle contraction. They are especially used for
strengthening the muscle mass. Only perform the electrical muscle stimulation programme
on intact and healthy muscles. Because they involve muscle contraction, they need to be per-
formed at rest (lying or sitting).
When using for the first time, the electrical stimulation can lead to a atypical and strange sen-
sation. It is advisable to begin the programme on low intensity and change to a higher one to
become used to it. The stimulation must remain comfortable and muscle contractions must not
be harsh or painful. If your programme is part of intensive physical exercise or after effort, you
are advised to choose a low intensity to limit muscular fatigue.
Summary Table of the EMS Programmes
EMS
Treatment
Treatment
Treatment
Name
site
time
phases
Phase 1
Phase 2
Resistance
Shoulder
of the
28mn
trapezoid
Phase 3
Phase 4
40
BewellConnect - BW-TS1 - User Manual - 072015
On : 0,25s
100Hz
150
BURST
Off : 0,25s
Continuous
100Hz
200
CONT
output
40Hz (5s)
250
Continuous
6Hz (10s)
250
CONT
output
50Hz (5s)
250
Impulses
Frequency
Width
Wave
Description
(time)
in µS
form
Preparation
5Hz (5mn)
280
phase
Intensity :
50%
55Hz (10s)
280
Up : 1,5s
Down :
0,75s
EMS
6Hz (8s)
280
Intensity:
25%
Phase of
relaxation
3Hz (10mn)
280
Intensity :
40%
Phase 1
Phase 2
Resistance
Abdo-
of ab-
22mn
minal
dominal
muscles
Phase 3
Phase 4
Phase 1
Phase 2
Resis-
Lumbar
tance of
28mn
areas
the lower
back
Phase 3
Phase 4
BewellConnect - BW-TS1 - User Manual - 072015
Up : 10s
Con : 5s
30Hz (2mn)
200
Down : 10s
Rest : 5s
Up : 5s
Con : 5s
45Hz (9mn)
200
Down : 5s
Rest : 5s
EMS
Up : 6s
Con : 8s
60Hz (9mn)
200
Down : 6s
Rest : 5s
Up : 10s
Con : 5s
30Hz (2mn)
200
Down : 10s
Rest : 5s
Preparation
5Hz (5mn)
300
phase
Intensity :
50%
55Hz (10s)
300
Up : 1,5s
Down :
0,75s
EMS
Intensity:
6Hz (8s)
300
25%
Phase of
relaxation
3Hz (10mn)
300
Intensity :
40%