Operating the device safely
WARNING!
!
Do not operate the device in areas with combustible atmos-
pheres.
NOTICE!
A
Only use the connecting hose included in the scope of delivery.
Check the connecting hose before every use. Replace the con-
necting hose if it is damaged or soiled with oil.
Make sure that the refrigerant does not contain large quantities
of oil and is not in the hose in liquid form.
The initial pressure may not exceed 20.7 bar.
Replace the filter of the instrument as soon as the connecting
hose is soiled with oil.
Only connect the analytical device to the low-pressure side of
the cooling system.
Do not fill liquids or oil-containing refrigerant samples into the
analytical device.
NOTE
I
Place the device on a stable and and level surface.
Make sure that the air intake and the ventilation hoses of the
device are free.
3
Scope of delivery
No. in
fig. 1,
Description
page 3
1
Control and display module
2
Low-pressure coupling with filter
3
Manual pump for manual ventilation
4
Connection cable
14
Mini Identifier R-134a