Radio-controlled clock with indoor climate
• There are three different reception states:
Symbol flashing – reception is active
Symbol solid – reception is very good
No symbol – no reception/reception is deactivated/set time manually
• If the clock cannot detect the DCF-signal (e.g. due to interference, transmitting distance, etc.), the time can be set manually. The clock will then
work as a normal quartz clock. (see: Manual settings).
6.2.1 Note on radio-controlled time
The time base for the radio-controlled time is a caesium atomic clock operated by the Physikalisch Technische Bundesanstalt based in Braun-
schweig (Brunswick), Germany. It has a time deviation of less than one second in one million years. The time is coded and transmitted from Main-
flingen near Frankfurt via the frequency signal DCF-77 (77.5 kHz) and has a transmitting range of approximately 1,500 km. The adjustment to Day-
light Saving Time (summer/winter time) is automatic. The reception quality depends mainly on geographic location. Normally there should be no
reception problems within a 1,500 km radius around Frankfurt.
Therefore, please note the following steps:
• The recommended distance to any interfering sources like computer screens or TV sets is at least 1.5 - 2 meters.
• Within concrete walls (reinforced with steel) such as basements, the received signal is naturally weakened. In extreme cases, please place the
unit close to a window to improve reception.
• During night-time, the atmospheric interference is usually less severe and reception is possible in most cases. A single daily reception is ade-
quate to keep the accuracy deviation under 1 second.
7. Operation
• Press and hold the ▼ / SEC or ▲ / DM button in the respective setting mode for quick setting.
• The device will automatically quit the setting mode if no button is pressed for 15 seconds.
• When setting the time and the alarm time, make sure that 'PM' is shown on the display between 12:00 - 00:00 o'clock!

7.1 Manual settings

• Press and hold the MODE/SET button in normal mode for three seconds.
• RCC appears on the display and ON (default) will be flashing. By default, the DCF reception is activated and after successful reception of the DCF
signal no manual adjustment is necessary.
• Press the ▼ / SEC or ▲ / DM button if you want to deactivate the DCF reception (OFF).
• Confirm with the MODE/SET button.
• Press the MODE/SET button to make the settings in the following sequence: Time zone TZ (0 - default), the hours (hour hand is flashing, 12:00 –
00:00 o'clock = PM), the minutes (minute hand is flashing), the year, the month/day sequence (American version) or day/month (European ver-
sion), the month, the day and the day of the week language (GER - default) and the temperature unit (°C - default). Press the▼ / SEC or ▲ / DM
button to adjust it.
• Confirm with the MODE/SET button.
• Once the DCF time signal is successfully received and the DCF reception is activated, the manually set time is overwritten.
12
Seite 7
Radio-controlled clock with indoor climate
7.1.1 Time zone setting
• In the setting mode you can make the time zone correction (-12/+12).
• The time zone correction is needed for countries where the DCF signal can be received but the time zone is different from the DCF time (e.g.
+1=one hour plus).
7.1.2 Day-of-week language setting
• In the setting mode you can set the day-of-the week language: German (GER), English (ENG), French (FRE), Spanish (SPA), Dutch (DUT), Italian
(ITA), Polish (POL) and Czech (CZE).
7.1.3 Temperature unit setting
• In the setting mode you can change between °C (Celsius) or °F (Fahrenheit) as temperature unit.
7.1.4 Seconds hand setting
• Press the ▼ / SEC button in normal mode, to activate or deactivate the second hand.
7.1.5 Date format setting
• Press the ▲ / DM button in normal mode to select the month/day sequence (American version) or day/month (European version).

7.2 Alarm time setting

• Press the MODE/SET button in normal mode, to enter the alarm mode.
• ALARM TIME and 7:00 (default) or the last adjusted alarm time appear on the display.
• Press and hold the MODE/SET button.
• The hour hand flashes.
• Press the ▼ / SEC or ▲ / DM button to adjust the hours. Attention: 12:00 - 00:00 = PM!
• Confirm the setting with the MODE/SET button and set minutes in the same way.
• Confirm with the MODE/SET button.
• The set time appears on the display.
• Press the MODE/SET button again to return to the current time.
• The switch at the back allows you to choose between three different alarm functions (Mo-Fr., Mo-Sa, Mo-Su).
7.2.1 Activate and deactivate the alarm time
• To activate or deactivate the alarm function press the AL ON/OFF button in normal mode.
• The alarm symbol appears/disappears on the display.
• When the adjusted alarm time is reached, the alarm rings.
• Press any button and the alarm will stop.
• If the alarm is not stopped manually, the ascending alarm tone automatically turns off after two minutes and will be reactivated at the same set
time on the following day.
• The alarm symbol remains on the display.
• When the alarm rings, press the SNOOZE button and the snooze function is activated.
• Once the snooze function is activated, the alarm symbol will be flashing on the display.