Alba
MAINTENANCE
During all cleaning, maintenance, repair or adjustment operations on the product it is always required to disconnect the electrical power (in the
motorised model). It is advised to put a warning sign on the power supply main switch with the following indication: "Do not touch. Service
personnel at work". The use of ladders, scaffolding or other equipment is reserved to specialised personnel who must perform all operations in
compliance with current safety regulations, using the necessary PPE (Personal Protective Equipment).
Bioclimatics Albais a unique product incorporating design concepts and materials featuring top level quality and durability.
To maintain the product fully functional over time, perform the cleaning and control actions as per the following table:
Components
Cleaning and control actions
The rotating pins should be washed thoroughly with a jet of water, and if possible using a brush, removing all
Pins
traces of dirt and/or salt deposits, as indicated in Figure 1.
Attention: Never lubricate the rotating pins for any reason.
The hardware is stainless steel. It must be rinsed with a jet of water to remove any dirt and/or salt deposits.
The appearance of micro-oxidation, more frequent in maritime environments subject to salt spray, does not affect
Hardware
the quality and durability of the product. Such oxidation is normal.
If you need to eliminate these oxidised spots you can use a steel wool or a brush with stainless steel bristles. The
protective chromium oxide film (self-passivation) will be restored naturally just through exposure to air, without
any intervention by the user.
Clean the painted aluminium profiles with a mild cloth dampened with water and mild soap.
Aluminium
ATTENTION: Do not use acid to clean aluminium parts.
Make sure that the drainage pipes of the gutter and downspouts are clean.
Gutters
Eliminate leaves and other debris that may clog the drainage holes.
Gaskets and silicon
Check the proper operation of the gaskets and reposition them correctly if they have shifted. Periodically check the
seals
status of silicon seals, and if there is any deterioration, contact your Authorised Retailer.
Rev. 1 - 06.2018
CORRADI SRL - USER MANUAL
Attention:
1
Never lubricate
the rotating pins
for any reason.
Method for cleaning the rotating pins
In areas not exposed
In areas exposed
to salty air and smog
to salty air and smog
Once a year
Once a month
Once a year
Once a month
Once a year
Once a month
At least 4 times a year do a weekly check when there are leaves
or needles falling on the cover (e.g., Autumn)
Every 6 months
Every 6 months
11 of 14