PROCEDURE
1 Push down the Pusher Lever and release
the strip nails from the Pusher.
2 Push the Nail Stopper, and remove the strip
nails from inside of the Magazine.
3 Pull and stayed the Pusher with hand.
4 Remove the jammed nail from the Nose us-
ing a punch or a slotted screw driver.
Pusher Lever
Nail Stopper
Pusher
WARNING
When removing the jammed nail, wear the
gloves.
Do not remove the jammed nail with your bare
hands.
Magnet
Remaining nail
WARNING
Nails are held in the Nose of the tool by mag-
net. (SN883RH2 only)
This tool equips a magnet in the Nose to drive
out all nails loaded in the Magazine. Therefore,
in the case the collation strip is broken, there are
nails remaining in the Nose even if you think that
you removed whole nails. In this case, there is
possibility of serious accident if you think that
there are no nails and activate the tool. For that
reason, when you remove the nails from the
Magazine, confirm that there are no nails in the
Nose besides disconnect air supply.