Zibro R 617 E Instrucciones De Uso página 64

Ocultar thumbs Ver también para R 617 E:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
E
M
SWITCHING OFF THE HEATER
Push the OFF-button A. The flame will extinguish after a little while.
F
ADJUSTING THE WICK HEIGHT
After a period of time the combustion may no longer be high enough (Section D). In
that case you can adjust the wick height to improve the flame. To do this, the heater
N
must have been switched off. Follow the procedure below:
1 Push the OFF button A (Fig. M).
2
3
4
If adjustment of the wick height does not have the required effect, let the hea-
ter burn until all fuel has been used up (Section H).
If the flame height is still too low and the wick is set on position 3, then contact
O
your dealer, or replace the wick, refer to section M. If the flame gets too high after
adjusting (Fig R), the wick height lock should be placed one position lower again.
Otherwise smoke or soot may be caused.
G
MALFUNCTION, CAUSES AND SOLUTIONS
If any malfunctioning cannot be solved from the directions below, please contact
your dealer.
THE HEATER DOES NOT IGNITE
e
e
O).
e
IRREGULAR FLAME AND/OR SOOT AND/OR SMELLS
e
e
e
e
e
4
56
Pull the knurled wick adjustment knob B off the heater, so the wick height
lock K will be visible.
Take the plastic collar between your thumb and index finger and pull it out.
Turn the collar up one step, to either position 2 or 3 (Fig. N). Carefully push
the collar back, so the pin engages in the recess.
Carefully reinstall the knurled wick adjustment knob. This can be done in one
way only - check the rear of the cap for the correct position.
The batteries are not positioned correctly in the holder. Check (Fig. O).
There is not enough power left in the batteries for the ignition. Replace (Fig.
You have run out of fuel from the tank or the wick has been replaced.
After having refilled and replaced the removable tank, wait for 30 minutes
before igniting the heater.
The combustion chamber D has not been positioned correctly.
Use the handle E to put it level, until you can easily slide it slightly to the left
and to the right and the chamber is level.
You are using fuel which is past its 'use by' date.
Start every heating season with fresh fuel.
You are using the incorrect type of fuel.
Refer to THE RIGHT FUEL (See Section 'What you need to know in advance').
Dust has gathered in the lower part of the heater.
Contact your dealer.
Wick position wrong.
See Section F.