Emptying The Condensation Tank; Adjustment Of The Blow Direction - Trotec TTK 100 S Manual De Instrucciones

Ocultar thumbs Ver también para TTK 100 S:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
"Continuous" operation mode
The device dehumidifies the air constantly and re-
gardless of the amount of humidity in the air.
"Automatic defrost" operation mode
Upon cooling, the moisture in the room air condenses
and covers the evaporator fins with ice, regardless of
the air temperature and the relative humidity. Auto-
matic defrost switches on the defrost cycle when
necessary. During the defrost phase, dehumidifying is
temporarily paused and the defrost indicator light (8)
lights yellow. Automatic defrost is activated automati-
cally in "Normal" operation mode.

Adjustment of the blow direction

A.
B.
1. Ensure that the air can be blown out without inter-
ruption.
2. Ensure that the air is not blowing towards sensiti-
ve objects (e.g. plants).
3. To reach the maximum dehumidifying capacity,
completely open the upper air outlet flap (1).
B - 7

Emptying the condensation tank

A.
B.
C.
D.
Operating Manual - Dehumidifier TTK 100 S
EN
Tabla de contenido
loading

Tabla de contenido