8.
Storage
permissible storage temperature:
Permissible humidity:
bei Langzeitlagerung:
9.
Most Important Features
• Wide-range AC input without switching
• Protection class 2
• Primary side protected by internal circuit breaker
• 7 V and 12 V output voltage can be selected.
• Mounting for DIN rail according to EN 50022
10. Standards
Electrical safety is provided by means of a design in compliance with EN 60950
(VDE 0805). It meets the requirements and standards required for CE conformity
and carries the CE symbol.
11. Notes on Operation
Appliance cooling must not be impaired. In order to ensure an unimpeded flow of air,
a minimum distance of 15 mm to adjacent parts must be maintained.
Wiring connections to the connector terminals must only be made in an electrically
dead condition. Due to the type of protection used (IP 20), the device must be
operated in dry rooms only.
-40 °C ... + 85 °C
30 ... 95 % relative humidity; there must be
no condensation present when the system is
started up.
With long-term storage: Appliances with
built-in capacitors must be connected to
mains voltage for at least 5 minutes every
2 years.