Section 6

Troubleshooting

Symptom
Possible Causes
Quartz sleeve is stained or dirty
Change in feed water quality
High Bacteria
Contamination in water lines after UV
Counts
system
Possible break-through of sediment
through pre-filter
Common problem caused by
Heated Product
Water
infrequent use of water
Water Appears
Caused by air in the water lines
Milky
Problem with O-ring seal (on retaining
nut and/or UV sensor)
Chamber Leaking
Condensation on chamber caused by
Water
excessive humidity & cold water
Inadequate inlet/outlet port
connections
System Shutting
Interrupted controller
Down
Intermittently
Loose connection between lamp and
connector
Lamp Failure
Alarm on - New
Moisture build up in connector may
Lamp
keep lamp and connector from making
a solid connection
LED display reads "A3"
LED display is blank
Clean sleeve with scale cleaner and eliminate source of staining problem (ie. soften hard water,
refer to
Have source water tested to ensure that water quality is still within allowable limits for this system.
It is imperative that effluent water stream be shocked with chlorine (bleach) before water leaves UV
system - disinfection system must have a bacterial free distribution system to work effectively. Refer
to
Section 3.1
Have source water tested for turbidity - may need stepped filtration in order to catch all sediment
entering water system (20 micron filter followed by a 5 micron filter followed by UV system).
Run water until air is purged.
Ensure O-ring is in place, check for cuts or abrasions, clean O-ring, moisten with water/ lubricant
and re-install, replace if necessary (410867).
Check location of disinfection system and control humidity.
Check thread connections, reseal with Teflon
Disconnect lamp from connector and reconnect, ensuring that a tight fit is accomplished
Eliminate chance of any moisture getting to the connector and/or lamp pins
DISPLAY FAULT MODES
Lamp life expired - countdown is at "0" days
Press reset button for a deferred alarm, replace UV lamp
Controller is in lamp failure mode
Power system down, allowing it to reset itself; apply power in order to confirm that the controller is able to power lamp
Check to see if there is sufficient power to the UV system
Section
4.2.
Run water until it return to ambient temperature.
Install temperature management valve
Ensure system has been installed on its own circuit, as other equipment may be drawing power
away from UV (ie. pump or fridge).
UV system should not be installed on a circuit which is incorporated into a light switch.
Troubleshooting
Solutions
®
tape and re-tighten.