Furman F1000-UPS Manual Del Propietário página 11

Idiomas disponibles

Idiomas disponibles

Response from UPS:
$BANK 2 = ON<CR>
If UPS battery level < Shutoff Threshold
Action:
Turn off Outlet Bank 2
Response from UPS:
$BANK 2 = OFF<CR>
$BATTERY = charge%<CR>
If power button is OFF and state is changed to ON
Action:
Activate Power Button
Response from UPS:
$BUTTON = ON<CR>
If entered bank or state are invalid
Response from UPS:
$INVALID_PARAMETER<CR>
SET BANK 2 THRESHOLD
Sets the battery level threshold in which Outlet Bank 2 shuts off.
Send to UPS:
!SET_BATTHRESH level<CR>
level is a number between 20 and 100 represents the battery charge level where Outlet Bank 2 is shut off to the reserve re-
maining battery charge for the equipment connected to Outlet Bank 1. level shall be rounded up to the nearest interval of 10.
If level is >19 AND level <101
Action:
SHUTOFF THRESHOLD will be set to a value between 20 and 100.
Response from UPS:
$BTHRESH = level<CR>
If specified level is invalid
Action:
No action will be taken
Response from UPS:
$INVALID_PARAMETER<CR>
SET BUZZER MODE
With Buzzer Mode ON, the buzzer will sound during UPS Mode.
Send to UPS:
!SET_BUZZER mode<CR>
mode = {ON, OFF}
If specified mode is invalid
Action:
No action will be taken, UPS will request a valid mode setting
Response from UPS:
$INVALID_PARAMETER<CR>
$BUZZER = mode<CR>
SET AVR MODE
Sets AVR (Automatic Voltage Regulation) MODE.
Command:
!SET_AVR mode<CR>
mode = {OFF, STANDARD, SENSITIVE}
If specified mode is invalid
Action:
No action will be taken, UPS will request a valid mode setting
11

Capítulos

loading

Productos relacionados para Furman F1000-UPS