Disposal And Recycling; Troubleshooting Guide - Aerotec Airliner Silent Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
Warning!
Store the compressor only in a dry location which is not
accessible to unauthorized persons.
Always store upright, never tilted!

8. DISPOSAL AND RECYCLING

The unit and its accessories are made of various types of material,
such as metal and plastic.
Defective components must be disposed of as special waste. Ask your
dealer or your local council.

9. TROUBLESHOOTING GUIDE

Note: Remove power source and drain tank pressure prior to making any repairs or adjustments.
FAULT
Reduction of performance. Frequent start-
up. Low pressure values.
The compressor stops and restarts
automatically after a few minutes.
After a few attempts to restart, the
compressor stops.
The compressor does not stop and the
safety valve is tripped.
Any other type of operation must be carried out by authorized Service Centers, requesting original parts. Tampering with the machine
may impair its safety and in any case make the warranty null and void.
Warranty and repair.
In the event of defective goods or requirements for spare parts, kindly contact the sales point where you made your purchase.
CAUSE
Excessive performance request, check for
any leaks from the couplings and/or pipes.
Intake filter may be clogged.
Tripping of the thermal cutout due to
overheating of the motor.
Tripping of the thermal cutout due to
overheating of the motor (removal of the
plug with the compressor running, low
power voltage).
Irregular functioning of the compressor or
breakage of the pressure switch.
13
REMEDY
Replace the seals of the fitting, clean or
replace the filter.
Clean the air ducts in the conveyor. Ventilate
the work area.
Activate the on/off switch. Ventilate the work
area. Wait a few minutes. The compressor
will restart independently.
Remove the plug and contact the Service
Center.
G
B
Tabla de contenido
loading

Tabla de contenido