Electrical Power Requirements; Electrical Wiring; Extension Cords; Grounding Instructions - Pro Force VSF1080421 Manual Del Operador

Tabla de contenido
SPÉCIFICATIONS DE L'ALIMENTATION ÉLECTRIQUE

ELECTRICAL WIRING

Refer to the air compressor's serial label for the unit's
voltage and amperage requirements.
Use a dedicated circuit
For best performance and reliable starting, the air
compressor must be plugged into a dedicated circuit, as
close as possible to the fusebox or circuit breaker. The
compressor will use the full capacity of a typical 15 amp
household circuit. If any other electrical devices are drawing
from the compressor's circuit, the compressor may fail to start.
Low voltage or an overloaded circuit can result in sluggish
starting that causes the motor overload protection system or
circuit breaker to trip, especially in cold conditions.
NOTE: A circuit breaker is recommended. If the air
compressor is connected to a circuit protected by a fuse, use
dual element time delay fuses (Buss Fusetron type "T" only).

EXTENSION CORDS

NOTE: Avoid use of extension cords.
For optimum performance, plug the compressor power
cord directly into a grounded wall socket. Do not use an
extension cord unless absolutely necessary. Instead, use a
longer air hose to reach the area where the air is needed.
If use of an extension cord cannot be avoided, the cord
should be no longer than 50 feet and be a minimum wire size of
12 gauge (AWG). Do not use a 16 or 14 gauge extension cord.
Use only a 3-wire extension cord that has a 3-blade
grounding plug, and a 3-slot receptacle that will accept the plug
on the product. Make sure your extension cord is in good
condition. An undersized cord will cause a drop in line voltage,
resulting in loss of power and overheating. The smaller the
gauge number, the heavier the cord.

GROUNDING INSTRUCTIONS

This product should be grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
This product is equipped with a cord having a grounding
wire with an appropriate grounding plug. The plug must be
plugged into an outlet that is properly installed and grounded in
accordance with all local codes and ordinance.
DANGER
Improper installation of the grounding
plug can result in a risk of electric shock. If repair or
replacement of the cord or plug is necessary, do not
connect the grounding wire to either flat blade
terminal. The wire insulation having an outer surface
that is green with or without yellow stripes is the
grounding wire.
This product is for use on a nominal 115 volt circuit. A cord
with a grounding plug, as shown here, shall be used.
Make sure that the product is connected to an outlet
having the same configuration as the plug (see Figure 4). No
adapter should be used with this product.
Check with a licensed electrician if the grounding
instructions are not completely understood, or if in doubt as to
whether the product is properly grounded. Do not modify the
plug provided; if it will not fit the outlet, have the proper outlet
installed by a licensed electrician.
200-2786

ELECTRICAL POWER REQUIREMENTS

REQUERIMIENTOS DE ALIMENTACIÓN ELÉCTRICA
CÂBLAGE ÉLECTIQUE
Pour vous renseigner sur les normes d'intensité et de
tension de l'appareil, référez-vous à l'étiquette du numéro de
série du compresseur d'air.
Utilisez un circuit séparé
Pour obtenir le meilleur rendement possible et une
mise en marche fiable, le compresseur d'air doit être
installé sur un circuit séparé, aussi près que possible
d'une boîte à fusibles ou d'un disjoncteur. Le compresseur
utilise toute la capacité d'un circuit à usage domestique typique.
Si d'autres appareils électriques tirent du courant sur le circuit
du compresseur, il est possible que le compresseur ne puisse
pas démarrer. Si la tension est insuffisante ou si le circuit est
surchargé, le démarrage risque d'être lent et d'entraîner en
conséquence le déclenchement du disjoncteur ou de
l'interrupteur de remise en marche du moteur, surtout s'il fait
froid.
REMARQUE : Il est recommandé d'utiliser un disjoncteur.
Si le compresseur est branché sur un circuit protégé par un
fusible, utilisez des fusibles temporisés à double élément (Buss
Fusetron de type «T» seulement).

RALLONGES

REMARQUE : Évitez d'utiliser des rallonges.
Pour obtenir un rendement optimum, branchez le câble
d'alimentation du compresseur directement sur une prise de
courant mise à la terre. N'utilisez pas de rallonge sauf
nécessité absolue. Utilisez plutôt un tuyau flexible plus long
pour atteindre la zone où l'air est nécessaire.
S'il l'utilisation d'une rallonge est inévitable, le cordon
électrique ne doit pas dépasser 15 m (50 pi) et doit être d'un
calibre minimum de 12 (AWG). N'utilisez pas une rallonge de
calibre 16 ou 14.
Utilisez seulement une rallonge à 3 fils munie d'une prise
de terre à 3 lames et une prise de courant à 3 fentes dans
laquelle la prise peut être branchée. Veillez à ce que la rallonge
que vous allez utiliser soit en bon état. Une rallonge de
dimension inférieure à celle préconisée causera une baisse de
tension sur la ligne qui se soldera par une perte de puissance
et une surchauffe. Plus le calibre est petit, plus la rallonge doit
être grosse.
Figure 4
9
Tabla de contenido
loading

Productos relacionados para Pro Force VSF1080421

Tabla de contenido