Gabarron ECOMBI PLUS Serie Instrucciones De Instalacion Y Uso página 28

Acumulador digital inteligente
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Access to the parameter
Change Value: Decrease
Confirm Value
WEEKLY CHARGE PERIOD SETTING
Weekly charging days (UP06 parameter)
Charging/Not Charging day 1
Advance to the next day
Use
and
to move on through the different parameters.
Use
to access the parameter you want to modify. Change the value using
the navigation keys
and
It is possible to save the changes and exit at any moment by pressing
Ecombi Plus general parameters that can be modified by the user are detailed
below:
- UP01: Initial % of storage charge.
- UP02: Starting time of reduced (off-peak) rate electric period.
- UP03: Ending time of reduced rate electric period.
- UP04: Starting time of the second reduced rate electric period. (if not
available set up 00:00).
- UP05: Ending time of the second reduced rate electric period. (if not
available set up 00:00).
- UP06: Charging days during the week.
- UP07: Temperature ambient sensor correction (values from -5ºC to 5ºC).
- UP08: Maximum working period of the balancing heating element in on
peak electric period. Set up this value to "0" to cancel the balancing
heating element operation in on peak electric periods. With balancing
heating operation cancelled, the charge correction will not operate and
the same charging level will be applied every day. (Default 5 hours)
- UP09: Excess of temperature protection during the charge, Degrees
higher than the comfort set point temperature (Auto Mode) or the
manual set point temperature (Manual Mode) when the charge is
interrupted. (Values 1,2,3,4 & 5).
- UP10: Degrees Celsius or Fahrenheit. (Values: ºC – F).
- UP11: Open Window Detection Activation. (On/Off).
- UP12: Adaptive Start Control Activation (On/Off).
- UP13: Kind of temperature control. Recommended & default PID.
ECOMBI PLUS does not change automatically from summer time to winter time
or vice versa when not connected to the internet. Depending on the tariff it may be
necessary to change the clock settings to fit these two timings.
Access to the general setting to modify the charging period of your Ecombi Plus
storage heater. (See "General Settings" above). By default, 23:00 to 07:00 charge
period is set in every day in the week.
Charge period
Two charging periods can be selected in the electronic control of your Ecombi
Plus.
- 1º Charging period: UP02 to UP03. (23:00 to 07:00 by default).
- 2º Charging period: UP04 to UP05. (Disabled by default, 00:00 to 00:00).
Weekly charging days
It is possible to select which days Ecombi Plus will charge and which days it will
not. Access to the UP06 parameter to modify the days you want your Ecombi
Plus takes a charge. (By default, 7 days of the week).
Access to UP06 parameter by pressing
the display and the charge condition (On/Off) is displayed.
Press
and
to change the charge condition for this day. Press
on through the days.
i
Ecombi Plus will not charge in Frost Protection time intervals. When setting a day
as "No charging day", Ecombi Plus will automatically set Frost Protection Temperature
in all time intervals of this day in the defined Auto Mode program. In addition, Frost
Protection Temperature will be set for this day in Manual Mode, setting the previous
set temperature for Manual Mode when the "no charging day" ends.
27
. Confirm the new value with
. The first day indicator in the top of
.
.
to go
Tabla de contenido
loading

Este manual también es adecuado para:

Eco158 plusEco208 plusEco308 plusEco408 plus

Tabla de contenido