After activation the motor
Current and voltage
is too loud. It is not possi-
too low
ble to suspend a load.
The capacitor is
damaged.
Unusually loud noises
Incorrect lubrication
Transmission and
bearing damaged due
to wear and tear
Incorrectly mounted
Incorrect power supply
No earthing
to hoist
Internal cabling in
contact with the
housing
The traverse mechanism
The traverse button
does not work
is faulty
The motor is unable to lift
Continuous operati-
the load
on leads to excessive
build up of heat in the
internal motor coils
and may even lead to
it burning out
Supply correct cur-
rent and voltage
Replace the capacitor
Apply more grease
Check and replace
transmission and
bearing if needed
Check assembly and
repair element ma-
king the noise
Check or connect
earth
Check internal cabling
Repair or adjust the
traverse button
Cool the motor and
then start it up as per
normal