CAM settings and reset. The CAM menu depends on the specific module. In the "CAM CONTROL" menu,
all the messages that come from the CAM when it is operating can be displayed; moreover, you can interact
with the CAM with the TPE programmer.

COMMON INTERFACE

Address setting menu in the event of more than one headend being connected to the distribution and selec-
confirm the settings by pressing the
tion of the operational module modes: master, slave, stand-alone.
In order to use the modules in the Master and Slave mode, perform the following procedure:
Make sure that the CAM and the smart card allow the simultaneous decoding of more than one program
belonging to the same transponder
Set the receiver in the correct mode (Master or Slave) by entering the "SETTING RECEIVER MODES"
menu
Connect the Master Module to its Slave modules by using the supplied flat cable
In the Master module, select the channels of the transponder under decoding that you want to supply
to the Slave modules. In order to do this, enter the "SETTINGS – CI PROGR. LIST" menu and add the
channels. The asterisk on the left of the program name (*) 1/N PROGRAM 1 shows that the program is
being decrypted.
See figure 13 for an example.
Procedure to modify the headend address in the event that more than one SIG9708CI unit is being used:
Enter the "SETTINGS" – "HEADEND ADDRESS" menu
Set the headend address number by using the arrows or the keyboard.
On the TPE display, the word "Wait ..." will appear (the wait can last up to 30 seconds)
Scan the modules: SETUP HEADEND --> SCAN HEADEND
The TPE checks the headend modules; when the number of installed modules is reached, press the "X"
key of the TPE
Enter the "HEADEND SETUP" menu
Save with the TPE "S" key.
SETTING
Choose the program the
CAM will decrypt
confirm the settings by pressing the
4.10 COMMON INTERFACE
CI MENU
CAM CONTROL
CAM RESET
4.11 SETTINGS
key; save the settings by pressing the S key after
the modules programmation
RECEIVER
STAND-ALONE
MODE
CI PROGRAM
1/N PROGRAM 1
LIST
ADD
REMOVE
HEADEND
0
ADDRESS
the modules programmation
Enter the OSD navigation of
theCAM
Reset hardware of the
CAM module
SLAVE
N/N PROGRAM N
Enter with
Confirm by
15
0, 1, ..., 15
key; save the settings by pressing the S key after
31
"not available" if the
CAM not insert
"not valid" if the CAM has not
messages to display
Stand-alone
Master
Slave
"Not available": module in
slave or stand-alone
mode
Add or remove the channel that
is to be available for the Slaves
modules
"Not allowed": operation cannot
be executed, programming
error.
"Not executed": receiver is busy,
try again .
Manual setting of the
headend address.