UK
Default Value of the Cycles
Please refer to the Dixel Controller manual for further information.
Cy1: for fast chilling and conservation of foods at positive temperature
CyS = tEP
dbC = yes
iS1 = 8°C
rS1= -10°C
Pd1 = 2.0 h
CyS = tEP
dbC = YES
iS1 = 8°C
rS1 = -10°C
Pd1 = 2.0 h
CyS = tEP
dbC = yes
iS1 = -18°C
rS1=-28°C
Pd1 = 4.0
CyS = tEP
dbC = yes
iS1 =-18°C
rS1=-28°C
Pd1 = 4.0

Cleaning the evaporator

Please ensure that the Blast Chiller is switched off and unplugged prior to cleaning
Clean the evaporator periodically.
As the fins of the evaporator are very sharp. always wear protective gloves for the next phases Only a brush
must be used for cleaning :do not use jets of liquid or sharp instruments.
To access the evaporator proceed as follows:
1.
Open the door (A) of the appliance.
2.
Loosen the two screws (B) on the right of the deflector.
3.
Remove the runner (C).
4.
Turn the deflector (D) to the left.
iS2 = 5°C
rS2 =+2°C
Pd2 = 3.0 h
iS3 = 5°C
rS3=+2°C
Cy2: for chilling and fast freezing of foods with holding
iS2 = 5°C
rS2= +2°C
Pd2 = 2.0 h
iS3=-18°C
rS3=-28°C
Cy3: direct fast freezing with holding
iS2=-18°C
rS2=-28°C
Pd2 =OFF
iS3 =-18°C
rS3=-28°C
Cy4: direct fast freezing without holding
iS2=-18°C
rS2=-28°C
Pd2 =OFF
iS3=-18°C
rS3=-28°C
Pd3 = OFF
dbH = yes
HdS = 2°C
Pd3 = 4.0 h
dbH = YES
HdS =-21°C
Pd3 = 4
dbH = yes
HdS = -21°C
Pd3 = OFF
dbH = no
HdS = OFF
8
Tabla de contenido
loading

Este manual también es adecuado para:

Ursus5Ursus10

Tabla de contenido