All of the assembled tools displayed are shown in basic setting 0.
When fitting the tool, the indexable insert must point in the direction of the positive adjustment direc-
tion (+) of the slider.
DE
DE
With the use of boring bars 4 and 5 as well as the cartridge holder 2, screw in grub screw D
= central coolant transfer.
Screw back screw C until the location bore is free. Insert the boring bar with the clamping surface
towards the screw. Clamp boring bar 4 or 5 using screw C to 5 Nm.
Loosen screw A.
Place tool on pre-setting device: adjust finely using graduated dial. Here, one turn of the graduated dial
corresponds to an ⌀-adjustment of 1 mm.
Using the scale, adjustments of 0.01 mm can be made from graduation to graduation or of 2 μm using
the vernier.
Clamp slider B to 6 Nm with screw A.