resideo Braukmann UMV500-LF Series Manual De Instrucciones página 3

Válvula termostática universal under sink
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Fig. 4. Place handwheel on adjustment rod.
Fig. 5. Adjust temperature.
MAINTENANCE
Test the valve annually to make sure that the internal
parts operate properly.
M36650
1. Turn on the hot faucet and run water for a few
minutes, until the hot inlet temperature is at its
maximum.
2. Remove the cap by pulling it off.
3. Use the cap upside down to adjust the outlet
temperature with a thermometer under the faucet.
Turn the hand wheel one-half turn clockwise for
cooler temperatures and counterclockwise for
warmer temperatures.
4. Check the outlet water temperature with a
thermometer to make sure that the temperature
changed and the hand wheel turned without
binding.
5. When the correct outlet temperature has been
reached, replace the cap to lock the setting.
M36651
3
Fig. 6. Lock the setting.
UMV500 SERIES
M36652
38-00056EFS—07
Tabla de contenido
loading

Este manual también es adecuado para:

Braukmann umv500-u series

Tabla de contenido