Wire Connections - SELVA MARINE Dolphin 9.9 Manual De Servicio

Tabla de contenido
ELEC
R
3
4
STARTING SYSTEM
R
2
1
SERVICE POINTS
FUSE (E MODELS)
1. Check:
9 Fuse holder
No continuity → Check the fuse hold-
er leads.
9 Fuse holder leads
No continuity → Replace.
Continuity → Check the fuse.
2. Check:
9 Fuse
No continuity → Replace.
Fuse rating:
12 V - 10/20 A

WIRE CONNECTIONS

1. Check:
9 Wire connections
Poor connections → Properly connect.
STARTER RELAY (E MODELS)
1. Check:
9 Starter relay condition
Out of specification → Replace.
Checking steps:
8 Connect the tester between the
starter relay terminals as shown.
Tester positive lead 1 →
Starter relay terminal
Tester negative lead 2 →
Starter relay terminal
8 Check that there is no continuity
between the starter relay terminals.
8 Connect the tester and battery
between the starter relay terminals.