D
Premium LED spotlight
PArTS DESCrIPTION (see Fig� A)
Screw for terminal box
1
Lustre terminal
2
Unlock button
3
Assembly plate
4
Screws for assembly plate
5
Cable bushing
6
Dowels
7
Motion detector
8
(Modell City SH 8005 PIR IP 44, City LH 8005 PIR IP 44 and City LH 562405 PIR IP 44)

SAFETy INSTruCTIONS

Notice: Please read the following instructions before your install the lamp. Make sure that the
current is shut off before you connect the lamp. The lamp may only be installed by a qualified
professional.
warning: This lamp may not be used without all of the o-rings properly installed! LED lamps are
extremely bright. Under no circumstance should you look into the LED lamp as this can cause
permanent damage to the eyes.
A broken LED cover must be replaced with a Brennenstuhl LED protection disc prior to continuing
to use the lamp.

TECHNICAL DATA

Nominal voltage:
Nominal power:
Protection type:
Protection class:
The LED lamp is solely for normal use and not designed for raw operation.
Motion detector range:
Duration:
Ambient temperature:
INSTALLATION
Notice: The lamp must be installed on a dry, stable and solid surface in accordance with the
specifications in Fig. B. Ideally, the LED lamp should be installed 1.8 to 2.5 above the ground (see
Fig. B).
8
BA_City_LED-Premium_0486444_150313.indd 8
220–240 V~ 50 / 60 Hz
80 x 0,5 W LED
IP 44
I
approx. 180 ° and max. 10 meter, adjustable
adjustable from 10 (+/– 5) seconds up to 4 (+/– 1) minutes
–15 °C – + 40 °C
13.03.15 09:20