Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
Pressing <-> with the display turned off means an impulse of P.P.
In the charts following the single available functions are described in the plant.
MENU
Automatic closure time. It is enabled only with "TCA"=ON logic.
TCA
At the end of the preset time, the control unit controls a closure
operation.
If it is memorized with the SAIR radio function, the partial opening width
is adjusted through the second channel of the transmitter. The TCA
Sair
automatic closure has no effect on the partial opening.
Partial opening is allowed only if the door is completely closed
The value is expressed in centimetres 1=10cm/30=300cm.
Adjustment of amperometric sensor sensitivity during normal speed in
PMo
opening*
1: maximum sensibility - 99: minimum sensibility
Adjustment of amperometric sensor sensitivity during normal speed in
PMC
closing*
1: maximum sensibility - 99: minim sensibility
Adjustment of amperometric sensor sensitivity during slowing down in
PSo
opening*
1: maximum sensibility - 99: minim sensibility
Adjustment of amperometric sensor sensitivity during slowing down in
PSC
closing*
1: maximum sensibility - 99: minim sensibility
It is activated only with SERL:ON logics.
TLS
The activation time of the service light is adjusted.
It regulates the tension belt release when the operator arrives to the
SPIN
mechanical stop in closing
The belt tensioning time is adjusted when the automatic system reaches
the stop in the closed position.
trmf
It is activated only through the SPIN:0 parameter.
Note: use the TRMF parameter if an optimal tensioning of the belt is not
obtained through the SPIN parameter.
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables multi-flat function.
On: multi-flat function enabled. The step-by-step and perdestrian commands
IBL
have no effect during the opening phase.
Off: multi-flat function disabled.
During the TCA phase, the PP controls are enabled or disabled.
IBCA
On: PP controls are disabled.
Off: PP controls are enabled.
The rapid closure is enabled or disabled. It can be activated only if TCA:ON
On: enabled rapid closure. With open gate, the photocell activation causes
SCL
the automatic closure after 3 s. If the photocell is activated during the opening
phase, the operation is completed and closure starts after 3s
Off: disabled rapid closure.
14
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
FUNCTION
A wrong formulation of these parameters can be dangerous.
Respect the regulations in force!
FUNCTION
* ATTENTION:
MEMO
MIN-MAX-(Default)
1-240-(40s)
3-25-(5)
1-99-(20%)
1-99-(20%)
1-99-(20%)
1-99-(20%)
1-240-(60s)
0-20-(3)
0-120 (30)
MEMO
DEFAULT
(OFF)
(OFF)
(OFF)
(OFF)