The loads are disconnected approx. 1 minute after a series of 25
signals.
Load status display
In case of deep discharge or overload/short-circuit of load, the
load output is switched off. This is indicated by:
Normal operation
(LED off)

Low Voltage Disconnect Function (LVD)

The controller has 2 different modes to protect the battery from
being deeply discharged:
State of charge controlled: Disconnect at 11.4 V (at nominal
1.
load current) up to 11.9 V (at no load current). Normal operation
mode for good battery protection.
Low voltage
disconnect (LED on)
28
Overload or
Short-circuit of load
(LED flashing)