3. How To Control The Unit
The DMX512 is widely used in intelligent lighting control,with
a DMX 512 controller.connect several lights together,dmx in
and dmx out, 3 pin XLR connectors: Pin 1: GND, Pin 2: Nega-
tive signal (-), Pin 3: Positive signal (+)
Display:
MENU To select the programming functions
DOWN To go backward in the selected functions
UP To go forward in the selected functions
ENTER To confirm the selected functions
Set DMX Address Code
1. Press "Menu" to "Set DMX Address",and press"ENTER"
keys to enter into
2. Show "Set DMX Address DMX Address:001",Press the "UP
and DOWN" keys to amended
3. Press "ENTER"keys to save and Exit,Press the"MENU"Keys
does not save and Exit