Doffing; Other Accessories; Technical Specifications - Sundstrom SR 500 Instrucciones De Uso

Ocultar thumbs Ver también para SR 500:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4.9 Doffing

Leave the polluted area before removing the respiratory
inlet covering and fan unit.
• Take off the respiratory inlet covering.
• Switch off the fan unit.
• Release the belt and remove the fan unit.
• After use, the SR 500 components must be cleaned,
inspected and prepared for reuse (e.g. charge the
batteries).

4.10 Other Accessories

A variety of optional components and accessories are
available for the SR 500 to afford the user flexibility in
selecting configurations of components to optimize
protection and comfort. Optional components include;
Hoods: SR 520 S/M, SR 520 M/L, SR 530
Face Shields: SR 540, SR 570
Helmet: SR 580
Helmet / Welding shield: SR 580 / SR 584
Full facepiece: SR 200
Half mask facepiece: SR 900
Battery: Heavy Duty 3.6 Ah
Particulate Filters: SR 510, SR 710
Chemical Cartridges: SR 532, SR 533
Flow Meter: SR 356
Belts: Rubber, Leather, Nylon
Use only components listed on the NIOSH approval
label in the approved configuration and in
accordance with the part numbers shown in the
Parts List Section 3.
Accessory components include:
Eyewear: SR 341
Welding Cassette: SR 84
Storage bag: SR 505
Cleaning tissues: SR 5226
Pre-filter holder: SR 512
Splash cover: SR 514
Harness: SR 552
Hose protection: SR 52091
Plug kit
The Plug kit is used for cleaning or decontamination of
the fan unit and prevents dirt and water from entering
the fan housing.
Disconnect the breathing hose and the filters and install
the plugs. Fig. 29.

5. Technical Specifications

SR 500 Fan Unit
Air flow rate
During normal operation, the air flow rate is at least
6.2CFM (175 l/min), which is the manufacturer's
recommended minimum flow rate or MMDF. On
boosted operation, the air flow rate is at least 7.9CFM
(225 l/min).
Shelf life
The SR 500 system has a shelf life of 5 years from the
date of manufacture. However, note that the battery
must be charged at least once a year.
Temperature range
• Storage temperature: from -20 to +40 °C at a relative
humidity below 90%.
• Service temperature: from -10 to +55 °C at a relative
humidity below 90%.
Battery
HD, Heavy Duty, 14.8 V, 3.6 Ah, lithium-ion.
• The charging time for the HD battery is about 2 h.
• The cycling life is about 500 full cycles.
Operating times
The operating times may vary with the temperature,
and the condition of the battery and filters.
The table below gives the expected operating times
under ideal conditions.
HD
Filter
3,6Ah
P100 /HE
P100 /HE
SR532
(with SR 510 P100/
HE filter)
SR533
(with SR510 P100 /
HE filter)
Air flow
Expected
rate
operating
time
175 l/min
13 h
225 l/min
8 h
175 l/min
8,5 h
225 l/min
5 h
11