Preparing Reports; Recommendations - CESVA LRF-05 Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Two zones can clearly be distinguished on this screen:
 Acoustic parameter zone (bottom): In this zone you can graphically consult the
continuous equivalent emission and reception levels, the emission and reception limits,
the maximum and minimum 1-minute continuous equivalent emission levels, and the
"Fast" level and its emission limit. The curves may be deactivated by pressing the right-
hand mouse button.
 Incidents zone (top): in this zone you can consult the information corresponding to
incidents: disconnections; emission, reception and fast exceeded; sensor unqualified;
insufficient line; and SLD and SLE.
By pressing the right-hand mouse button you can copy the graph that appears on the screen
to the Windows clipboard, and than paste this image onto any other programme. If you press
the left-hand mouse button on any point in the graph, the numerical values of all the sound
parameters and incidents will appear.

4.10 Preparing reports

The LRF-05 software allows you to write the following reports:
Programming report
Leq records numerical report
Session records numerical report
Leq records graphic report
The reports are generated by a report-generating motor which you can access by pressing
in the corresponding menu. This motor provides a preliminary image of the report and
allows you to select the printer and the pages of the report you want to print.
The reports are generated in the language selected from the main programme display.

5. RECOMMENDATIONS

To use the LRF-05 correctly, follow these instructions:
Make sure the LRF-05 is always connected to the mains.
Do not tamper with the seals placed by the authorities.
Do not tamper with the sensor.
The LRF-05 compensates for excess music level by applying attenuation to the signal
sent to the speakers. In order to work comfortably and at the maximum possible level, we
recommend that the LRF-05 attenuate between an average of 0 and 3 dB. Working with
high attenuations around 50 dB will not increase the sound level of the music, and once
50 dB are exceeded, the LRF-05 will apply restrictive attenuation, which means that the
music will not be heard.
 Make sure that the mains to which the LRF-05 is connected is properly earthed and
complies with low-tension regulations currently in force.
The LRF-05 is equipped with an internal memory fed by a 3.6 V rechargeable battery,
which allows it to keep all the measured data and configurations in the limiter even if the
12 V battery runs out. The average life of the 3.6 V battery is approximately 5 years
according to the manufacturer of the battery.
When this battery runs out, all data saved until that moment is lost. When this happens,
contact your official
This equipment only can work with the accessories mentioned in the accessories section.
In case that using a different accessories and that this causes a failure in the equipment,
would not be responsible of this failure. Then the equipment will lose its
warranty.
dealer to replace it.