Control de señales de entrada y salida
Encoder connection with external power supply:
Connector CON2 (PS/encoder)
(Product sensor, 7-pin)
+Ub external
+Ub internal
Enc. 'A'
Enc. 'B'
GND internal
GND external
With left-handed rotation of the encoder Pin3 must be exchanged with Pin7!
Figura 17
PS connection with external power supply:
Connector CON3 (I/O)
(I/O, 16-pin)
+Ub ext. OUT
PS input
GND ext.
With external power supply, jumper 1 (1-2; 3-4; 5-6) (default) may not be inserted!
Figura 18
Connection alarm relay:
Currentless and/or error
(Alarm, 4-pin)
F1 6,3AT
PE
If I/O connector is not used -> Jumper 1 (1-2 & 5-6) must be inserted
Figura 19
26
4
x
(brown/green)
5
x
3
(brown)
x
7
(green)
x
1
x
(white/green)
2
x
11
x
Prod.sensor (PS)
2
x
1
x
Connection alarm relay:
1
x
max. 230V/6A
2
x
3
x
4
x
Manual de usuario
(DC-isolated)
Encoder (right-handed rotation)
A1
B1
(DC-isolated)
+Ub external
24VDC +/- 10%
GND external
Ready:
(Alarm, 4-pin)
F1 6,3AT
PE
Dynacode IP
+Ub external
24VDC +/- 10%
GND external
1
x
max. 230V/6A
2
x
3
x
4
x
11.18