CONTROL PANEL NE266
GB
CONTROLS:
Push button with warning light for
turning INTERNAL LIGHTS on or off (*)
Push button with warning light for
turning AUX on or off (*)
(*) Green light colour active load, yellow light colour deactivate load
1
( ) On the back of control panel there is a 2way connector for additional push button to switch on or off the external light.
2
( ) Yellow light colour active load, flashing yellow light colour deactivate load
SCREENS:
The warning light goes on when the 230V mains is connected
The warning light goes on when
Press the push button to see internal temperature on the display (
temperature (
If the temperature probe is faulty the display will show "
Press this Key for viewing the level percentage % (0, 25, 50, 75, 100) of the drinking water tank with the symbols S1.
If S1 is empty, the display flashes.
Press this Key for viewing the level percentage % (0, 25, 50, 75, 100) of the recovery water tank with the symbols R1. If R1 is
full, the display flashes.
Press the push button once to see the voltage on the service battery (B2), Press the push button again to see displays the %
B2
the remaining battery.
Only in the view as %, if there is
battery charge.
Press the push button once to see the voltage on the
the remaining battery.
B1
Only in the view as %, if there is
battery charge.
Press this key for viewing the current on the service battery (B2). If the current is positive (battery
A
charging) will show the symbol +A; if the current is negative (battery discharging) will show the symbol -A.
The screen remains active for approx. 30 seconds. with the flashing light on the corresponding button pressed.
ALARMS:
Batteries: Car battery (B1) less than 11,8V or Service battery (B2) less than 10V.
In this case there is a bleep (if enabled) and the flashing battery button that have generated the alarm
(for the first 30 seconds you see the value). Hold for more than 3 seconds (
or enabled (show "
(show "
") or enabled (show "
Tanks:
Tank S1 empty or Recovery tanks R1 full. In this case there is a bleep (if enabled) and the flashing symbol the
corresponding tank that raised the alarm(for the first 30 seconds you see the value).
Hold for more than 3 seconds (
tanks
Beep:
Hold for more than 3 seconds (
confirmation beep button pressed, and alarm buzzers
This symbol appears when there is an error:
.
Serial cable connection is wrong
.
Pump output is short-circuited or overloaded
.
External light output is short-circuited or overloaded
.
A
ux/heating_tank output
CONSUMPTION:
To turn on the control panel you must touch for 1 sec. the right or left side panel where there are the keys.
The panel after 30 sec. switches to standby mode by turning off all symbols except the keys
keys light up when you touch for 1sec. the right or left side panel. On stand by (
module NE237 consumes a total of approx 40mA. When the key (
total consumption is reduced to just 4mA.
turns itself off, together with all live parts.
CONNECTIONS:
The back of the panel has a connector for serial connection (JP6), a connector for the optional external temperature probe
(JP10), a connector for the optional remote internal temperature probe (JP8) and a connector for additional push button to
external light switch (JP9).
ENABLE CLEANING GLASS:
Hold on the button (
) more than 5 sec will lock all the push button for 1 minute.
A
Push button with warning light
for turning PUMP on or off(*)
Push button with warning light for turn on LOAD( )
Hold on the button more than 2 second will turn off
Hold on the button more than 5 second will turn off the control panel
the vehicle engine is running and the parallel batteries is active
). If you get the message "
If the tank is wrongly connected, the display will show "
If the tank is wrongly connected, the display will show "
or
the displayed value is replaced with the moving segments to indicate the
or
the displayed value is replaced with the moving segments to indicate the
") the low car battery alarm. Hold for more than 3 seconds (
") the low service battery alarm
) button can be disabled (show "
) button can be disabled (show "
is short-circuited or overloaded
If the service battery voltage drops below 10V, after 1 minute the control panel
), press the push button twice to view external
", the temperature sensor is not present.
"
starter battery (B1)
, Press the push button again to see displays the %
no active controls
5 sec.) is pressed the control panel turns itself off and
7
Push button with warning light for turning
EXTERNAL LIGHTS on or off (*)( )
2
LOAD/ INTERNAL LIGHTS/ PUNP
".
".
) button can be disabled (show
B1
) button can be disabled
B2
") or enabled (show "
") the alarm of all
") or enabled (show "
") the the
and those of active loads.
) the control panel with
GB
1
2
( )
)