9. All other ERROR codes: Turn off the Key, and disconnect the positive battery cable from the Batteries for more than
one minute (the time is needed to drain the controller on-board capacitor). Reconnect cables, being sure that it is tight.
Too loose and you will burn battery. If you over tighten the cables you can damage the battery lead terminal. Try
again.
10. If the problems cannot be solved by any of this solution, call your local dealer service department.
- 34 -
5. 7700: Vacuum Motor circuit is open.
6. Throttle ERROR: You pressed the foot pedal before turning
on the Key. Turn off the Key and try again, leaving foot off of the
pedal.
7. 2C00 and 2C01 ERROR: Low voltage warning. Voltage has
dropped down below the minimum required to operate the ma-
chine. If you wait a few minutes, the Batteries may come up in
voltage, allowing you to drive very slowly to the recharge station.
If not, you will have to release the parking brake (on the front
wheel, pull lever toward the front of the machine to release) and
push the machine to recharging station. You must disconnect the
traction motor! (+ cable fi rst)
8. 7802 ERROR: The traction motor pulled excessive current
perhaps running a ramp for more than the 60 seconds allowing
for this. Turn off the Key, turn on again, and continue. You should
not use this machine to climb ramps so steep and so long that
this code comes up repeatedly, or you could overheat the traction
motor.