Configuring The Pagematrix Controller - Peavey PAGEMATRIX Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5.5. Configuring the PageMatrix Controller

As mentioned previously, the PageMatrix controller supports up to sixteen paging stations
simultaneously. In larger applications where multiple controllers are necessary, the various
PageMatrix units must be configured for IDs beyond the default 1-16 setting. This is accomplished
by changing the DIP switch settings inside the unit.
1. Remove top plate of the controller (six screws).
2. Now viewing the inside of the unit, find the DIP switch (labeled SW100) located at the front left
side of the unit.
3. You will only adjust switches 1 and 2 according to the chart below.
4. Switches 3 through 8 are inactive.
DIP SETTINGS
1 2 3 4 5 6 7 8
O
N
1 2 3 4 5 6 7 8
O
N
1 2 3 4 5 6 7 8
O
N
1 2 3 4 5 6 7 8
O
N
NOTE:
Factory settings default to 1-16
26
CONTROLLER IDs
Stations 1 - 16
Stations 17 - 32
Stations 33 - 48
Stations 49 - 64
Tabla de contenido
loading

Tabla de contenido