Cover for riser extension (optional)
• After setting up the lift columns, lift the cross-con-
nection to the opposite side and fasten it. The hy-
draulic lines are placed in the cross-connection.
• Guide the lines from above into the riser of the
opposite side and connect to the colour marked
positions.
• Fasten the extension using the long screws (8)
after the tensioning plate (7) has been placed.
7
Tensioning plate
8
Fastening screws
54
004
7 8
005
4.8 First filling
• When filling the hydraulic system, identify already
filled cylinders (with the sticker "first filling" on the
system) and unfilled cylinders (no sticker on the
system).
• Lifts with this sticker already have hydraulic oil in
the hydraulic cylinders.
4.8.1 First filling with sticker
• Required oil volume 9 l (HLP 32).
Lifts with this sticker already have
hydraulic oil in the hydraulic cylinders.
• After setting up the electrical connection to the
lift, the hydraulic system can be filled.
9
11
9
Operating lever
10
Allen key operating lever
11
Oil filling opening
• Loosen and remove the plastic part of the
operating lever (9) of both Allen screws (10).
• Loosen and remove the unit cover.