Beko DRYPOINT M PLUS Serie Instruciones De Instalación Y De Servicio página 2

5
english
1. Liability for defects
Please read this information very carefully:
Liability for defects can only be accepted if the following rules
and the instructions for installation are complied with.
Provided appropriate CLEARPOINT filters are being used and
the filter elements are replaced once a year, the purchaser of
the compressed-air membrane dryer shall be entitled to claim
remedy of defects within 2 years from date of invoice.
BEKO shall not be liable for damage due to improper or incor-
rect use, wear, storage or other actions by the purchaser or
third parties.
This applies in particular to wearing parts.
2. Temperature
There must be no danger of frost at the place of installation; the
temperatures at the place of installation and of the compressed
air should be between +35 and + 140 °F.
2
Important Notes • Indicaciones importantes
5
4
6
3
2
DRYPOINT DM 10-34 C-N, DM 10-41 C-N, 10-47 C-N, 20-48 C-N, 20-53 C, 20-60 C-N, 20-67 C-N
4
5
4
6
1
3 : integrated Nano filter
nanofiltro integrado
3. Filters
Please observe the relevant filter requirements (see page
8 - 9):
Dirt particles, oil residues and liquid condensate have to be
safely retained.
For these purposes a CLEARPOINT nanofilter N (0,01µ) is
integrated in the membrane dryer housing. With high dirt loads
or large amounts of condensate, it will be necessary to install
a CLEARPOINT F fine filter (1 µm) in addition and, where ap-
propriate, a CLEARPOINT W water separator.
Note: The filter elements need to be replaced once a year.
Caution: maintenance works must be carried out only when
the device is pressureless!
This applies for the replacement of the nanofilter as well
which is an integrated part of the membrane dryer:
- Remove bottom part of the membrane dryer housing (fine
thread). In doing so hold the upper part tight in its posi-
tion.
- check the float drain and replace it, if required (FAD055)
- Exchange the filterelement and reassemble the two body
parts and screw tight
5