Sears CRAFTSMAN 919.177153 Manual Del Usuario página 16

Idiomas disponibles

Idiomas disponibles

5.
Run the compressor for 20
minutes. Make sure the globe
valve is open and there is
minimal air pressure build-up in
tank.
6.
Check all air line fittings and
connections/piping for air leaks
by applying a soap solution.
Correct if necessary. NOTE:
Minor leaks can cause the air
compressor to overwork,
resulting in premature breakdown
or inadequate performance.
7.
Check for excessive vibration.
Readjust or shim air compressor
feet, if necessary.
8.
After 20 minutes, close the globe
valve. The air receiver will fill to
"cut-out" pressure and the motor
will stop.
Before Each Start-Up:
1.
Place On/Auto/Off lever to
"OFF".
2.
Close the globe valve.
3.
Attach hose and accessories.
NOTE: A regulator MUST be
installed when using accessories
rated at less than 175 PSI.
D26064
hazardous risk of bursting. Check
the manufacturer's maximum
pressure rating for air tools and
accessories. The regulator outlet
pressure must never exceed the
maximum pressure rating.
How to Start
1.
Turn the On/Auto/Off lever to
"AUTO" and allow tank pressure
to build. Motor will stop when
tank pressure reaches "cut-out"
pressure.
2.
When the tank pressure reaches
"cut-out" pressure open the
globe valve.
IMPORTANT: When using regulator
and other accessories refer to the
manufacturer-s instructions.
NOTE: Always operate the air
compressor in well-ventilated areas
free of gasoline or other combustible
vapors. If the compressor is being
used to operate a sprayer, DO NOT
place compressor near the spray
area.
16-ENG
Too much air
pressure causes a
loading

Este manual también es adecuado para:

Craftsman 919-17715-ca