Key Automation HALO Serie Instrucciones Y Advertencias Para Su Instalación Y Uso página 12

Motorreductor para puertas de garaje
EN
4.16 - Using the display programmer
To customise the programmer's language, proceed as follows:
OPTIONS
DISPLAY
N.B.: When the display is turned on for the first time, the user
will be prompted to select a language. Press ▲ or ▼ to select
the desired language and then confirm with V.
If no language is selected (press the X key), the control unit will
use the default language (ENGLISH) until the next power-on.
In normal mode, i.e. when the system is powered on normally
and the display programmer is connected, press X until the
wording "Key Automation" is displayed. In this way, you will
be able to view the following status messages:
EVENT
opening
ventilation opening
closing
automatic closing
stop in closing
stop in opening
open
open in ventilation
closed
programming
obstacle
photo!
sensitive edge!
partial opening
partial automatic closing
ventilation automatic closing
FLASH/LED error
phototest error
limit switch error!
memory error
4.17 - KUBE PRO / KUBE wireless module connection
Before carrying out any operation, power off the equipment.
Remove the plastic protection cover of the KUBE module connector.
Remove the plastic shells (FIG. 49) and insert the card in its special
input slot (FIG. 50).
ATTENTION !
Once removed from its container, handle the KUBE module
with extreme care.
ATTENTION !
Carefully check the position of the KUBE module on the control
unit connector (FIG. 50).
With the KUBE PRO and DYL programmers it is possible to change,
in addition to the parameters (TAB. 3), the following parameters:
opening speed* - slowing speed in opening* - closing speed* -
slowing speed in closing* - slowing extent in opening* - slowing ex-
tent in closing* - phototest - sensitive edge test - partial opening
extent - garage ventilation function extent - partial automatic closing
time - ventilation automatic closing time - flashing operation mode
- pre-flashing time - light intensity at end of movement - integrated
12
LANGUAGE
SELECTION
DESCRIPTION
Door opening
Door opening for ventilation
Door closing
Open door with timed closing active
Door stopped in closing phase
Door stopped in opening phase
Door fully open without automatic closing
Door open in ventilation without automatic closing
Door fully closed
During the programming phase
Detected motor obstacle
Photocell operation
Sensitive edge operation
Partial opening in progress
Partial door opening with active timed closing
Open door in ventilation with active timed closing
FLASH and LED output overload
Phototest error detected
Limit switch/mechanical stop error detected
Memory error detected
KEY AUTOMATION
SCROLL UP
CANCEL
SCROLL DOWN
2 fast flashes + pause + 1 flash
4 fast flashes + pause 3 times
2 fast flashes + pause 3 times
5 fast flashes + pause 3 times
6 fast flashes + pause 3 times
3 fast flashes + pause 3 times
8 fast flashes + pause 3 times
10 fast flashes + pause 3 times
courtesy light operation - operation after power failure - flashing
activation for maintenance - default - input lock with password -
receiver lock with password - stop contact.to change follow the in-
structions on the screen.
* After adjusting the parameter it is mandatory to control at
least two complete operations to allow the control unit to store
the motor stress throughout the stroke
ATTENTION !
CONFIRM
FLASHING INDICATION AND
CONTROL UNIT CONTROL LEDS
loading