Xylem JABSCO 58500 Serie Manual De Instalación Y Funcionamiento página 5

Inodoros eléctricos de bajo caudal
Ocultar thumbs Ver también para JABSCO 58500 Serie:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
Option 3: Toilet discharging into holding tank
AND top of holding tank above non-return valve
at any time.
YOU MUST FIT a 1-1/2" (38mm) Vented Loop fitting, Jabsco
part number 29015-0010.
• If there is ANY possibility that the discharge non-return valve
may be below the top of the tank at ANY time, a ventilated
anti-syphon loop must be fitted in the outlet pipework to
ensure that the contents of the tank do not syphon out
through the bowl.
• Arrange the outlet hose to form a loop which is at least 8"
(20cm) above the highest possible level that the top of the
tank may reach, and fit the Vented Loop at that highest point.
Option 4: Toilet discharging into holding tank,
AND non-return valve always above the top of
holding tank.
• Run the outlet hose by the most direct route from the non-re-
turn valve down to the holding tank inlet.
CONTROLS AND ELECTRICS
HAZARD WARNING: Flooding
FIT ISOLATION SWITCH IN POWER
SUPPLY!
The toilet should be switched off at all times when not in use.
Please ensure an electrical isolation switch is fitted in the power
supply to the toilet. If you do not and an electrical fault occurs with
the controller or rinse pump, water may flood in causing the craft
to sink, which may result in the loss of life.
YOU MUST:
• Connect the toilet power supply to a primary distribution
board with sufficient spare amperage capacity.
• Keep the total length of both the positive and negative wires
to a minimum, selecting your wire size from the Electrical
Specifications table below.
CAUTION: Inadequate wire size will result in voltage
drop, and will reduce performance.
• Make all joints with appropriately rated marine grade terminal
blocks and crimp connectors.
• Use marine grade multi-strand copper wire.
• Support all wires approximately every 18" (46cm) with plastic
cable clips.
CAUTION: YOU MUST FIT the correct size of fuse-
holder or circuit breaker, selected from the Electrical
Specifications table.
Control Panel
CAUTION: Remove fuse, or turn circuit breaker off,
whilst installing Controls and Electrics.
• Select a position for the Control Panel (key 31) that is conve-
nient for both standing and seated users, and which allows
you to run the 10ft (3m) control cable to the toilet.
• To use the Jabsco Fascia Panel provided, (key 32) drill a 5⁄ 8 "
(16mm) hole for the 6 way control cable connector. Screw the
control panel (key 31) onto selected location with suitable
counter sunk head screws. Clip on fascia panel (key 32).
• To use Gewiss fascia panels remove the four screws tabs (see
picture below). Cut a rectangular hole 2" (51mm) x 3-1/2"
(89mm). Fix panel (key 31) to selected location with four
counter sunk head screws. Clip on Gewiss fascia panel.
• To use Vimar fascia panels remove the four screw tabs (see
picture below) Cut a rectangular hole 2" (51mm) x 3-1/2"
(89mm). Place adaptor (key 33) onto panel (key 31) and screw
into place with four counter sunk head screw. Clip on Vimar
panel onto adaptor.
• Slide the Heat Shrink Sleeve (key 30) over the control cable.
Plug in the 6 way control cable to the toilet, and carefully use a
hot air gun or hairdryer to seal the Heat Shrink Sleeve over the
6 way connector.
• Note that the toilet has 2 other leads - Red and Black. Connect
your boat's Positive (+) feed to the Red (+) lead, and your
boat's Negative (-) return to the Black (-) lead.
Foot-switch
• Connect your boat's Positive (+) feed to the Red (+) lead, and
your boat's Negative (-) return to the Black (-) lead.
Cut along indented lines on
either side and pull off
screw tabs
CAUTION: Do not put anything in the toilet unless
you have eaten it first, except toilet paper.
Securing the toilet
• Bolt down the base toilet ensuring that the Foot-switch (key
24) and/or the blank (key 28) are located correctly. Make sure
that the cable from the Foot-switch is located in the guide and
not trapped.
• With Control Panel fit 2 blanks, with Foot-switch fit 1 blank on
respective side.
• Before fitting the seat and lid, if required, you may rotate the
upper part of the toilet and offset the angle of the seat to the
base.
• To rotate the top, loosen the two screws in the clamp (key 4)
and rotate to the desired position, retighten clamp screws.
• The top may be rotated 68° each side but, you will need to fit a
longer 3/4" (19mm) inside diameter rinse inlet pipe (key 15).
Testing
• Ensure that the battery is fully charged, and that the circuits
are live.
• Open both Seacocks.
• Refer to the next section - OPERATING INSTRUCTIONS.
• To prime the Rinse Pump on first installation, operate the Fill
and Flush buttons several times until water flows into the
bowl. The foot-switch may have to be pressed several times
until water flows into the bowl.
Safety
Ensure that this INSTRUCTION MANUAL reaches the owner, skipper
or operator of the craft as it contains essential safety information.
5
Screw into place with four counter
sunk head screws
loading