The wall mounting bracket must be able to support at least 4 times the weight of
the outdoor unit.
Step 4. Installation of the cable. Fig. 19
4.1 Use a Phillips screwdriver to unscrew the cable cover, grasp it and gently press it
off.
4.2 Unscrew the cable clamp and remove it.
4.3 In accordance with the wiring diagram pasted inside the cable cover, connect the
connecting wires to the corresponding terminals and make sure that all connections
are tight and secure.
4.4 Reinstall the cable clamp and cable cover.
NOTE:
When connecting the indoor and outdoor unit cables, the power must be cut off.
Fig. 19 key:
1.
Terminal block
2.
Cable clamp
3.
Cable cover
4.
Wiring diagram
5.
Outdoors
6.
Power supply
7.
Inside
Step 5. Connect the coolant pipe. Fig. 20
5.1 Unscrew the valve cover, grasp it and press it gently to remove it (if the valve cover
is applicable).
5.2 Remove the protective covers from the end of the valves.
5.3 Remove the plastic cover from the tube ports and check if there is any other in the
connecting tube port and make sure that the port is clean.
5.4 After aligning the centre, turn the flare nut of the connection pipe to tighten the
nut as tight as possible by hand.
5.5 Use a spanner to hold the valve body and use a torque spanner to tighten the flare
nut in accordance with the values in the torque requirements table.
(Refer to the torque requirements table in the INSTALLATION PRECAUTIONS section).
Fig. 20 key:
1.
Connecting pipes
2.
Remove the valve cover
3.
New flared