EVVO CLIMA 9000 Manual De Instrucciones página 98

Aire acondicionado
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
ENGLISH
operation.
III.
Make the coolant pipes, fit them, connect the drain hose, and wrap them as in
steps 4 to 7.
3.3 Installation of the outdoor unit
Step 1. Select the installation site. Fig. 16
Select a site that allows the following:
1.1 Do not install the outdoor unit near sources of heat, steam or flammable gas.
1.2 Do not install the unit in very windy or dusty places.
1.3 Do not install the unit where people often pass by. Select a location where the air
discharge and operating sound will not disturb the neighbours.
1.4 Avoid installing the unit where it will be exposed to direct sunlight (otherwise, use
a shield, if necessary, which should not interfere with airflow).
1.5 Reserve the spaces as shown in the figure for free circulation.
1.6 Install the outdoor unit in a safe and solid place.
1.7 If the outdoor unit is subject to vibrations, place the rubber blankets on the feet of
the unit.
Step 2. Installation of a drain hose. Fig. 17
2.1 This step is only for heating pump models.
2.2 Insert the drain gasket into the hole at the bottom of the outdoor unit.
2.3 Connect the drain hose to the joint and make the connection tightly enough.
Fig. 17 key:
1.
Drainage joint
2.
Drain hose
Step 3. Installation of the outdoor unit. Fig. 18
3.1 In accordance with the installation dimensions of the outdoor unit, mark the
installation position of the expansion bolts.
3.2 Drill the holes and clean the dust from the concrete and place the bolts.
3.3 If applicable, install 4 rubber blankets in the hole before attaching the outdoor unit
(optional). This will reduce vibrations and noise.
3.4 Fit the base of the outdoor unit to the pre-drilled holes and bolts.
3.5 Use a spanner to fix the outdoor unit firmly with the bolts.
NOTE:
-
The outdoor unit can be fixed on a wall mounting bracket.
-
Follow the instructions on the wall mounting bracket to fix the bracket on the
wall, and then fix the outdoor unit on it and keep it horizontal.
98