Open flames prohibited
2.
Operational security
Pay attention to static electricity
Wear protective clothing and antistatic gloves.
3.
Safety of the installation
Note that:
1.
The installation site must be well ventilated.
2.
Locations for installation and servicing of an air conditioner using R32 refrigerant
must be free from open fire or welding, smoke, drying oven or any other heat
source greater than 548 that readily produces open fire.
3.
When installing an air conditioner, it is necessary to take appropriate anti-static
measures, such as wearing anti-static clothing and/or gloves.
4.
It is necessary to choose a suitable location for installation or maintenance, the
air inlets and outlets of the indoor and outdoor units must not be surrounded by
obstacles or close to heat sources or flammable and/or explosive environments.
5.
If the indoor unit leaks refrigerant during installation, the outdoor unit valve
must be closed immediately and all personnel must leave until the refrigerant
drips completely for 15 minutes. If the product is damaged, it is imperative to
bring the damaged product to the service station and it is forbidden to solder the
refrigerant pipe or perform other operations at the user's site.
6.
It is necessary to choose a place where the air inlet and outlet of the indoor unit
is uniform.
7.
It is necessary to avoid places where there are other electrical products, power
sockets, kitchen cabinet, bed, sofa and other valuables just below the lines on
both sides of the indoor unit.
Ventilation required
Do not use a mobile
phone