EVVO CLIMA 9000 Manual De Instrucciones página 118

Aire acondicionado
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
ENGLISH
Insufficient air flow
either hot or cold
The device does
not respond to
commands
The display is off
Turn off the
air conditioner
immediately and cut
off the power supply
in the event of a
power failure:
Fault codes on the display
In the event of a fault, the indoor unit display shows the following fault codes:
Display
Error description
E1
Indoor ambient temperature sensor failure
E2
Inner tube temperature sensor failure
E3
Outer tube temperature sensor failure
E4
Leakage or failure of the coolant system
E6
Indoor fan motor malfunction
E7
Outdoor ambient temperature sensor failure
E0
Internal and external communication failure
E8
External discharge temperature sensor failure
118
EVVO CLIMA 9000/12000/18000/24000
Inappropriate temperature setting
Clogged air conditioning inlets and outlets
Dirty air filter
Fan speed set to minimum
Other sources of heat in the room
Without refrigerant
The remote control is not close enough to the indoor unit.
Remote control batteries need to be replaced.
Obstacles between the remote control and the signal
receiver in the indoor unit
Activate the DISPLAY function
Supply fault
Strange noises during operation
Defective electronic control board
Faulty fuses or circuit breakers
Spraying water or objects into the apparatus
Overheated cables or plugs
Very strong odours coming from the appliance
loading

Este manual también es adecuado para:

Clima 12000Clima 18000Clima 24000