Cardin Elettronica PRG900 Serie Manual Del Usuario página 11

Programador electronico para el control de las puertas motorizadas
Ocultar thumbs Ver también para PRG900 Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Terminal board connections
1- 2 M1 power supply motor 1
3- 4 M2 power supply motor 2
5
CMN common for all inputs and outputs
ELS electric lock output (fed continuously) 12 Vdc - 15 W
6
7-8 LC-CH2 Potential free contact for the activation of the courtesy light (separate
power supply Vmax=30 Vac/dc: Imax=1A) or the second radio channel.
Selection is carried out using jumper "J5"
9
LS 24 Vdc 3 W output for an indicator light
10
LP 24 Vdc 25 W output for warning lights
intermittent activation (50%), 12,5 W continuous activation
11
24 Vdc controlled output, powering external loads
12
CMN common for all inputs and outputs
CMN common for all inputs and outputs
13
14
24 Vdc output, powering external loads
15
CMN common for all inputs and outputs
FC1 (N.C.) gate 1 closing travel limit input
16
17
FA1 (N.C.) gate 1 opening travel limit input
18
FC2 (N.C.) gate 2 closing travel limit input
FA2 (N.C.) gate 2 opening travel limit input
19
20
CMN common for all inputs and outputs
21
TAL (NO contact) limited opening button input
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
TA (NO contact) opening button input
22
23
TC (NO contact) closing button input
24
TD (NO contact) dynamic button input
CMN common for all inputs and outputs
25
26
TB (N.C./8.2 kΩ) stop button input (The opening of this contact interrupts the
cycle until a new movement command is given)
27
CSP (N.C./8.2 kΩ) safety edge input. Opening this contact will provoke a travel
direction inversion during the closing stage and during the opening stage
28
FTCS (N.C./8.2 kΩ) The opening of this contact will block all movement, until
the obstruction has been removed and the pause time has elapsed, due to
the safety device cutting in, the door will then continue moving in the closing
direction (only with automatic reclosing enabled)
FTCI (N.C./8.2 kΩ) safety and control devices in input (photocells invert the
29
travel direction when an obstruction is detected). Opening this contact will
provoke a travel direction inversion during closure due to the cutting in of the
safety device
(2)
30
CMN common for all inputs and outputs
J2
J1
L2
F3
Fuse F4A
F1
Fuse F4A
M1
M2
1
2
3
B1
Signal buzzer "via radio" mode
D1
Six-segment LED display
DS1
Selection dip-switch
F1
4A
fuse (24V circuit protection)
F2
4A
fuse (electric lock protection)
F3
4A
fuse (24V circuit protection during battery operation)
F4
10A fuse (motor power protection)
F5
10A fuse (motor protection during battery operation)
J1
Battery connection
Drawing number :
DC0535
(1)
(1)
(2)
(2)
Fuse F10A
F4
F2
LC/CH2
5
6
7
8
9
10
11
12
4
Description :
31-32-33 Not connected
34
Outer conductor for radio receiver antenna.
35
Inner conductor for radio receiver antenna (if an external antenna is fitted use
a coaxial type cable RG58 with an impedance of 50Ω).
Note
The total of the 2 external device outputs must not exceed 10 W.
(1)
Note
The selection of the type of contact (N.C./8.2 kΩ) is carried out using parameter
(2)
"SC" on the six-figure display.
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently the security
device test must also be deactivated (FTCI , FTCS - Dip 9 and Dip 10 "OFF").
If you want to activate the FTCI, FTCS test both the transmission and receiver parts
of the security devices must be connected to the binding post marked "CTRL 24
Vdc". If the test is active there will be a 1 second delay between the command
transmission and movement of the gate/s.
Switch on the power and make sure that the indicator LEDs are in the following
condition.
-
L1
Power on
-
L2
Wrong battery connection
-
L3
Transmitter code programming indicator
-
L4
Indicator for the blocking button "TB"
-
L5
Indicator for the inverting photoelectric cells "FTCI"
-
L6
Indicator for the stop photoelectric cells "FTCS"
-
L7
Indicator for the safety edge "CSP"
-
L8
Indicator for the opening button "TA"
-
L9
Indicator for the opening button "TC"
-
L10 Indicator for the limited opening button "TAL"
-
L11 Indicator for the sequential command "TD/CH1"
Note
(3)
If this LED is "ON" invert the battery power cables immediately.
(2)
Note
Check that the activation of the safety devices switches the corresponding
(4)
LEDs off.
If the green power on LED "L1" doesn't light up check the condition of the fuses
and the power cable connection at the transformer primary.
If one or more of the safety LEDs do not light up check the contacts of the
relative security devices and check that the unused safety device contacts have
been bridged.
BC
L4
L1
F5
L5
L6
DS1
P1
13
14
15
16
17
18
19
20
21
J2
Transformer secondary protection
J3
Radio channel selection
J4
Enable transmitter memorisation via radio
J5
Binding posts 7, 8 selection (courtesy light/CH2 via radio)
MM
Transmitter code memory module
P1
Programming button (PROG)
P2
Transmitter code memorization button (MEMO)
P3
Transmitter code cancellation button (DEL)
R1
Radio frequency module, 433 MHz for S449 transmitters
Collegamenti scheda base
11
J3
34
J4
L7
L8
L10
MM
D1
L11
L9
P2
L3
P3
B1
J5
CSER
1 2
1 2
3
3
Pos.1 Pos.2
22
23
24
25
26
27
28
29
30
CS 1435
DC 0535
ON
OFF
(3)
OFF
ON
(4)
ON
(4)
ON
(4)
ON
(4)
OFF
OFF
OFF
OFF
2
35
R1
31 32 33
Tabla de contenido
loading

Este manual también es adecuado para:

Prg900 v01

Tabla de contenido