LIMITATIONS
SUB 3S electropumps are suitable to pump clear water that contains no dissolved gases.
The electropumps of SUB 3S series are multiphase centrifugal and submergible pumps.
WARNING
The electropump cannot be used to move inflammable or dangerous liquids.
WARNING
Verify that the electropump never runs without liquids.
TECHNICAL DATA
Mains voltage / frequency
Absorbed power
Type of protection / Insulation class
Delivery fitting
Maximum flow rate *
Maximum head *
Maximum immersion depth
Power cable
Weight
Maximum dimension of pumped solid particles
Maximum admitted working pressure
Maximum diameter of the well
Maximum temperature of the pumped fluid
Maximum number of starts per hour
Minimum priming level (A)**
Connection level (C)**
Stop level (D)**
(*) The specifications hereunder are referred to a configuration with a free and unreduced delivery mouth
(**) Measurements are expressed in millimetres.
Sound pressure level (Lpa) equal to or less than 70 dB(A)
Sound emission values obtained in conformity with the EN 12639 standard
8
SUB 3 S
230 V ~ 50 Hz
800 Watt
IP 68 / F
41,90 mm (1"1/4 M)
6.000 l/h
30 m
8 m
10 m
7,4 Kg
≤ 2 mm
7 bar
500 mm
40° C
30, equamente distribuiti
30 mm
340 mm
185 mm