Opening your life
- Do not allow children to play with door controls. Keep remote controls away from children.
- Watch the moving door and keep people away until the door is completely opened or closed.
- Take care when operating the manual release since an open door may fall rapidly due to weak or broken springs, or being
out of balance.
- Frequently examine the installation, in particular check cables, springs and mountings for signs of wear, damage or imba-
lance. Do not use if repair or
adjustment is needed since a fault in the installation or an incorrectly balanced door may cause injury.
- Each month check that the drive reverses when the door contacts a 50 mm high object placed on the oor. Adjust if neces-
sary and recheck since an incorrect adjustment may present a hazard, for drives incorporating an entrapment protection
system depending on contact with the bottom edge of the door.
- Details on how to use the manual release.
- Information concerning the adjustment of the door and drive.
- Disconnect the supply when cleaning or carrying out other maintenance.
- The installation instructions shall include details for the installation of the drive and its associated components.
Basic function introduction
1) Soft start, soft stop
Minimize start-up load on garage door opener and garage door
2) Opening & closing force self-learning
3) Overloading force detecting, the door will reverse more than 15cm automatically when it is overloaded when closing and
will stop when it is overloaded when opening.
4) Safety resistance adjustable, with a wide range, sensitive and reliable.
5) Low-voltage protection, the process will not perform any action of opening and closing when voltage is too low, door
panel and controller won´t be damaged.
6) We adopt rolling code transmitter, with billions of codes, won´t be coincident code or pirated code.
7) With auto-closing feature.
8) Metal chassis
9) Backup battery interface available, in case of power failure.