Maintenance
Replacing timer unit
X See page 15/2 ABC.
X Repeat steps from paragraph
First installation to reset LED.
Replacing filter cartridge
and resetting timer
Filter must be replaced after 500 L of
water. After replacing filter cartridge,
reset timer.
X To replace filter cartridge refer to
ilustration on page 15/3.
X To reset timer for 3 seconds push
button inside reset timer hole.
LED light will blink 3 times. After
LED light turns OFF, system is
ready.
Operating data
Operating pressure (ideal)
Operating pressure (max.)*
Operating pressure (min.)*
Water temperature (ideal)
Water temperature (max.)
* Equal pressure is recommended.
Periodic checks
X Check connection and shower
hoses periodically for the
following:
– Watertightness
– Corrosion
– Mechanical damage.
X Use original spare parts only.
X Replace damp or dripping hoses.
Replace hoses with rusty or
oxidized surfaces.
X Replace hoses that show signs of
mechanical damage.
X Flush all pipes thoroughly before
re-installation.
Value
3 bar
45 PSI
5 bar
70 PSI
1 bar
14.5 PSI
60 °C
140 °F
80 °C
180 °F
20
300 kPa
500 kPa
100 kPa