Step three: If the adjustment is completed, press the selection knob and con rm the parameter; Or
the system will con rm the parameter automatically after 3 seconds.
If the adjustment is
completed, press the
selection knob and con rm
the parameter; Or the
system will con rm the
parameter automatically
after 3 seconds.
4.7. TIG operation
Adjust 'welding mode selection switch' to TIG mode. If in TIG 4T mode and the output pulse function
is turned on, all parameters (7~17) of TIG can be adjusted. If in TIG 2T mode and the output pulse
function is turned on, the start current and crater current is 5A; If the pulse function is closed, the
parameter of base current(12), pulse frequency(17) and pulse width(13) cannot be adjusted.
TIG parameters adjustment: The welding current (10) can be adjusted directly when the welder is
tune on. Adjust the selection knob , the welding current LED (10) is twinkling; It means the welding
current can be adjusted. If the adjustment is completed, con rm the parameter by pressing the
selection knob or the system will con rm the parameter automatically after 3 seconds.
Other parameters adjustment: Take 'pre ow time' for an example. Press the selection knob ; Adjust
the selection knob and select the pre ow time LED (7 is on); Press the selection knob again, the pre
ow time LED (7) is twinkling; It means the pre ow time can be adjusted. If the adjustment is
completed, con rm the parameter by pressing the selection knob ; or the system will con rm the
parameter automatically after 3 seconds. Operation ow as follows:
Step one: 'Welding mode selection switch' select TIG 4T or 2T. Press the selection knob ;