4.6 TOOLS NECESSARY FOR INSTALLATION OF THE ACTUATOR
5. INSTALLATION
5.1 INSTALLATION WARNINGS
On windows with bottom hinged opening there is the danger of injury caused by accidental falling of the window.
It is NECESSARY to install limiting arms (type 1276 series of the Comunello Frame Division line) or an alternative
safety system, suitably sized to resist any accidental falling of the window.
5.1.1 MINIMUM PANEL HEIGHTS
Refer to the table for the values of the minimum heights of the panels relative to the chain motors in the bottom hung inward
opening version.
Chain stroke "C"
5.2 INSTALLATION SEQUENCE
-
Check that the width of the window where the actuator is to be installed is greater than 400 mm. Otherwise, it is NOT
POSSIBLE to fit the actuator.
-
Check that the force required to open/close (calculated according to the table in section 4.2) is less than or equal to that
indicated in the DATA TABLE.
-
Manually verify the opening of the panel, checking and eliminating any sticking areas that may give rise to malfunctions.
-
Manually check the maximum opening of the door by checking that it is greater than the stroke to be set on the actuator.
Do not retract the chain before attaching it to the frame.
200 mm
250 mm
300 mm
360 mm
INDICATION OF DIMENSIONS
Fulcro rotazione motore
50
Cerniera rotazione anta
13.5
H min panel
450 mm
750 mm
1050 mm
1400 mm
23