Hilti KCF 4-22 Manual De Instrucciones Original página 19

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
Status
One (1) LED quick-flashes yellow
One (1) LED shows yellow
One (1) LED quick-flashes red
3.4.2
Indicators showing the battery's state of health
To check the battery's state of health, press the release button and hold it down for longer than three
seconds. The system does not detect a potential malfunction of the battery due to misuse, for example
battery dropped or pierced, external heat damage, etc.
Status
All LEDs show in sequence, followed by one (1)
LED showing constantly green.
All LEDs show in sequence, followed by one (1)
LED quick-flashing yellow.
All LEDs show in sequence, followed by one (1)
LED showing constantly red.
4
Technical data
4.1
Product information
Rated voltage
Weight in accordance with EPTA-Procedure 01, without battery
Ambient temperature for operation
Storage temperature
4.2
Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
5
Preparations at the workplace
WARNING
Risk of injury by inadvertent starting!
▶ Before inserting the battery, make sure that the product is switched off.
▶ Remove the battery before making any adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
*2419422*
Meaning
The Li-ion battery or the product in which it is in-
serted is overloaded, too hot or too cold, or experi-
encing some other fault.
Bring the product and the battery to the recom-
mended working temperature and do not overload
the product when it is in use.
If the message persists, consult Hilti Service.
The Li-ion battery and the product in which it is
inserted are not compatible. Consult Hilti Service.
The Li-ion battery is locked and cannot be used.
Consult Hilti Service.
Meaning
The battery can remain in use.
The check to ascertain the battery's state of health
did not complete. Repeat the procedure, or consult
Hilti Service.
If a connected product can still be used, the re-
maining battery capacity is below 50 %.
If a connected product can no longer be used, the
battery has reached the end of its useful life and
has to be replaced. Consult Hilti Service.
2419422
21.6 V
3.4 kg
−17 ℃ ... 60 ℃
−20 ℃ ... 60 ℃
21.6 V
See the section headed "Intend-
ed use"
−17 ℃ ... 60 ℃
−20 ℃ ... 40 ℃
−10 ℃ ... 45 ℃
English
17
loading

Productos relacionados para Hilti KCF 4-22