SOFTWARE INTERFACE
The dose grinding times can be set by clicking inside the relative cell (2.1, 2.2 and
2.3) and using the regulation buttons (2.4). To confirm the desired time, click on the
confirmation button (2.5).
For the manual dose, there are two possible operating modes.
If the time is set to "0", the button works in continuous grinding mode for
20-minute cycles each time the button is pressed. Vice versa, if the time is set
with a value other than "0", the button works as "dose time 3".
3.
5
MENU
3.
1
DOSES
3.3
TECHNICAL
4.
6
TECHNICAL 1/3
4.
1
Grinder
Grinder
Wear
Switch
4.2
ON
OFF
button
4.
3
Filter
ON
OFF
holder radar
4.
9
ON
OFF
Password
Button 4.1 opens the "Grinder wear" page (para. 5).
To confirm the settings of buttons 4.2 and 4.9 click on the confirmation button (4.5).
Button 4.9 opens the "Change password" page (para. 6).
Using button 4.2 it is possible to activate or deactivate the dispensing mode (4.3), shown in
point 1.12 of the Home Page (para. 1). If the switch button 4.2 is deactivated, dispensing
is only possible using the controls in the Home Page (1.1, 1.2 and 1.4). If it is active,
dispensing occurs by pressing switch button
44
3.2
COUNTERS
3.4
DISPLAY
4.
8
FW Rel
4.
7
4.
5
4.4
3 MENU
3.
1
Settings/Doses: access (para.2)
3.
2
Counters: access (para.9)
3.
3
Technical: access (para.4)
3.
4
Display: access (para.10)
3.
5
Home: return (para.1)
4 TECHNICAL 1/3
4.
1
Grinder wear: access (para.5)
Switch button activation/deactivation
4.
2
4.
3
Switch button dispensing mode**
4.
4
Password setting
4.
5
Confirmation button
Home: return (para.1)
4.
6
4.
7
Technical 2/3: access (para.6)
Software version*
4.
8
Password activation/deactivation
4.
9
(pg. 33).