Ensure that the unit is well ventilated. Inhaling gas (which may contain oil residues) escaping from the
pump during operation can be harmful to human health.
The drained oil must be taken care of in accordance with environmental regulations.
When you have finished filling with oil, make sure that the unit is placed in its normal position. Do not tip it
over or allow it to lie on its side.
Troubleshooting
Error code
Causes
When the machine is vacuuming
E01
for some time, the pressure switch
doesn't close.
When the machine goes into
E02
sealing mode, the micro switch
doesn't close.
Machine loses power during the
LP
working.
DISPOSING OF USED DEVICES:
Do not dispose of this device in municipal waste systems. Hand it over to an electric and electrical device
recycling and collection point. Check the symbol on the product, instruction manual and packaging. The
plastics used to construct the device can be recycled in accordance with their markings. By choosing to
recycle you are making a significant contribution to the protection of our environment.
Contact local authorities for information on your local recycling facility.
EN
1 – Screw Cap; 2 – Spanner
Troubleshooting
1. Check if the lid is closed tight.
2. Check if the gasket is installed in right
position.
3. Check if the pump is working or not.
4. Check the pressure switch system is in
normal working or not (hose, pressure
switch and 10P data cord)
1. Check if the lid is closed tight.
2. Check if the micro switch system is in
normal working or not (GAS1 cable, micro
switch, 10P data cord)
1. Check the power supply.
2. Check the power supply system of
machine (power cord, 10P data cord)