Technical data
Problem
The display shows
"Error 35"
The display shows
"Error 40"
12
Technical data
Item number:
Dimensions (width x height x depth)
Weight:
Power supply:
Refrigerant extraction rate:
Vacuum pump output:
Hermetic compressor output:
Drier filter output:
Filling cylinder accumulator capacity:
Noise emission:
Accuracy of the electronic scale for refrigerant:
Accuracy of the electronic scale for old/new oil:
Accuracy of the electronic scale for UV additive:
Operating temperature range:
128
Cause
Residual pressure in the air
conditioning system.
Pressure drop during
pressure test.
ASC5000 RPA
Remedy
Drain and evacuate.
Check air conditioning
system and connections for
leaks.
AirConServiceCenter
ASC5000 RPA
8885200102
560 mm x 1300 mm x 650 mm
100 kg
230 V/240 V–50 Hz/60 Hz
30 kg / hr
5 cars / hr
0.32 kW
150 kg
16 kg
55.5 dB (A)
± 10 g
± 1 g
± 1 g
+ 5 °C to + 50 °C
EN