STORAGE
When not in use, always leave the saddle and ram all the way down.
Place the handle in the upright position.
Store the crane in a dry indoors location.
CLEANING
If the moving parts of the equipment are obstructed, use cleaning solvent and lubricate the parts. Remove
any existing rust, with a penetrating lubricant.
TROUBLESHOOTING
Will not
Will not
lift load
hold load
X
X
X
X
X
X
X
X
Safe operating temperature is between 4°C - 41°C (40°F-105°F)
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Will not
Poor
Will not
lower
lifting
lift to full hight
X
X
X
X
X
X
Tel.: 02196 720480
Fax.: 02196 7204820
Release valve is not completely closed
(Turn handle clockwise)
Weight capacity exceeded
Air is in the hydraulics
(Purge air from system)
Low oil level.
X
(Add oil as required)
Oil level to high
(Drain excessive oil)
Components are stuck
(Lubricate moving parts)
Objects under the crane
(Remove item)
Hydraulic unit malfunctioning
(Replace the Hydraulic unit)
Cause (Solution)
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed