ENGLISH
MAINTENANCE
Make sure the area below the installation place is free from unwanted persons during servicing.
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit9s optics.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Clean the external optics at least once every 30 days.
Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
Fuse:
Total Power consumption:
Sound Control:
DMX connections:
DMX channels:
DMX starting address:
Laser Power:
Laser radiation class:
Beam diameter @ aperture:
Divergence (each beam)
Divergence (total output)
Working temperature:
Laser Safety Standard:
Size:
Weight:
You can download the latest version of this user manual on our website: www.jb-systems.eu
®
JB SYSTEMS
AC 100~240V, 50/60Hz
250V 1A slow blow (20mm glass)
30W
Internal microphone
3pin XLR male / female
1 or 10 channels
001 512
40mW Green CW laser (λ = 532nm)
200mW Blue CW laser (λ = 450nm)
3B
<5mm
<2 mrad
<160°
15°C to 40°C
EN/IEC 60825-1 Ed2, 2007-03
see picture below
2,6kg
Every information is subject to change without prior notice